Piab P5010_AVM™2
- P5010_AVM™2
- P5010_AVM™2
- P5010_AVM™2
- By Piab
- FREE Shipping on orders of $2,000 or more
Overview
Features
- P5010 multistage ejector with Pi, Si or Xi COAX® push-in cartridge(s).
- AVM™2, Automatic Vacuum Management, unit with built-in control and monitoring functions.
- Valves for vacuum on/off, blow-off, blow-off flow control and non-return valve.
- Option with Normally Closed "fail safe" on/off valve (NC). It changes to an open valve if power is lost and vacuum will be generated. A conventional normally closed on/off valve (NC 2) is also available. It stays closed if electrical power is lost or removed.
- Option with automatic blow-off (1 sec) reduces number of outputs needed from PLC or I/O box.
- Enhanced blow-off effect thanks to a directed blow-off pipe.
- Analog vacuum sensor with two digital outputs, 16 pre-set combinations of signal levels to choose from.
- Digital display with “-kPa” or “-inHg” as unit options.
- Integrated energy saving function (ES) that minimizes the air consumption in sealed systems. The ES function can be activated manually or via a signal (signal override).
- Three-color LED status indicators for valves, signal outputs and ES.
- Material: Nitrile (NBR);Al;CuZn;PA;PE;PMMA;SS
- Weight (Max): 720 oz.
- Item Feed Pressure (Max): 0.7
- Item Noise Level (Min): 68
- Item Noise Level (Max): 71
Description
Ejector Data Specifications
| Ejector Specification | Pi48-2 |
| Feed Pressure | MPa | 0.3 |
| Air Consumption | Nl/s | 2 |
| Vacuum (Max) | -kPa | 90 |
| Vacuum Flow at 0 -kPa | Nl/s | 2.8 |
| Vacuum Flow at 10 -kPa | Nl/s | 2.5 |
| Vacuum Flow at 20 -kPa | Nl/s | 1.8 |
| Vacuum Flow at 30 -kPa | Nl/s | 1.1 |
| Vacuum Flow at 40 -kPa | Nl/s | 0.65 |
| Vacuum Flow at 50 -kPa | Nl/s | 0.5 |
| Vacuum Flow at 60 -kPa | Nl/s | 0.35 |
| Vacuum Flow at 70 -kPa | Nl/s | 0.25 |
| Vacuum Flow at 80 -kPa | Nl/s | 0.1 |
| Evacuation Time to Reach 10 -kPa | s/l | 0.038 |
| Evacuation Time to Reach 20 -kPa | s/l | 0.084 |
| Evacuation Time to Reach 30 -kPa | s/l | 0.153 |
| Evacuation Time to Reach 40 -kPa | s/l | 0.267 |
| Evacuation Time to Reach 50 -kPa | s/l | 0.441 |
| Evacuation Time to Reach 60 -kPa | s/l | 0.677 |
| Evacuation Time to Reach 70 -kPa | s/l | 1.01 |
| Evacuation Time to Reach 80 -kPa | s/l | 1.581 |
Need Help? Call an engineer at 1-802-880-3123