Call for pricing
  • P3010_AVM™2
  • P3010_AVM™2

Overview

Features

  • Patented multistage COAX® cartridge - MINI - with Pi, Si, Xi cartridge.
  • AVM™2, Automatic Vacuum Management, unit with built-in control and monitoring functions.
  • Valves for vacuum on/off, blow-off, blow-off flow control and non-return valve.
  • Option with Normally Closed "fail safe" on/off valve (NC). It changes to an open valve if power is lost and vacuum will be generated. A conventional normally closed on/off valve (NC 2) is also available. It stays closed if electrical power is lost or removed.
  • Option with automatic blow-off (1 sec) reduces number of outputs needed from PLC or I/O box.
  • Analog vacuum sensor with two digital outputs.
  • Digital display with “-kPa” or “-inHg” as unit options.
  • Integrated energy saving function (ES) that minimizes the air consumption in sealed systems. The ES function can be activated manually or via a signal (signal override).
  • Three-color LED status indicators for valves, signal outputs and ES.
  • Material: Nitrile (NBR);Al;PA;PMMA;SS
  • Weight (Max): 330 oz.
  • Item Feed Pressure (Max): 0.7
  • Item Noise Level (Min): 66
  • Item Noise Level (Max): 68

Description

Ejector Data Specifications

Ejector Specification Pi12-3
Feed Pressure | MPa 0.32
Air Consumption | Nl/s 0.44
Vacuum (Max) | -kPa 90
Vacuum Flow at 0 -kPa | Nl/s 1.4
Vacuum Flow at 10 -kPa | Nl/s 0.6
Vacuum Flow at 20 -kPa | Nl/s 0.44
Vacuum Flow at 30 -kPa | Nl/s 0.27
Vacuum Flow at 40 -kPa | Nl/s 0.19
Vacuum Flow at 50 -kPa | Nl/s 0.14
Vacuum Flow at 60 -kPa | Nl/s 0.1
Vacuum Flow at 70 -kPa | Nl/s 0.06
Vacuum Flow at 80 -kPa | Nl/s 0.03
Evacuation Time to Reach 10 -kPa | s/l 0.08
Evacuation Time to Reach 20 -kPa | s/l 0.23
Evacuation Time to Reach 30 -kPa | s/l 0.49
Evacuation Time to Reach 40 -kPa | s/l 1
Evacuation Time to Reach 50 -kPa | s/l 1.7
Evacuation Time to Reach 60 -kPa | s/l 2.6
Evacuation Time to Reach 70 -kPa | s/l 3.9
Evacuation Time to Reach 80 -kPa | s/l 6.3