- 1072RH
- 0127837
Overview
Features
- Two-stage COAX® cartridge MINI Pi12-2 integrated.
- Check valve that traps vacuum in sealed applications for safe operation.
- Built-in blow off check valve for fast release of object.
- Integrated energy-saving device, Vacustat results in virtually no air consumption in sealed applications.
- Available in lock pin 16, 19 or ball joint mountings, industry standard.
- Available with level compensator to compensate for differences in level of object.
- Recommend using 4mm (5/32”) tubing and no more than 80 psi for blow off.
- Recommend using 6mm (1/4”) tubing and no more than 80 psi for vacuum.
- Equal line lengths from common manifold should be used for both blow-off and vacuum.
- Maximum of (12) units per tool.
- Material: Nitrile (NBR);Al;CuZn;PA;PP;SS;Steel;Ceramic
- Weight (Max): 602 oz.
- Item Feed Pressure (Min): 0.25
- Item Feed Pressure (Max): 0.55
- Item Noise Level (Min): 66
- Item Noise Level (Max): 68
Description
Ejector Data Specifications
| Ejector Specification | Pi12-2 |
| Feed Pressure | MPa | 0.17 |
| Air Consumption | Nl/s | 0.29 |
| Vacuum (Max) | -kPa | 49 |
| Vacuum Flow at 0 -kPa | Nl/s | 0.57 |
| Vacuum Flow at 10 -kPa | Nl/s | 0.4 |
| Vacuum Flow at 20 -kPa | Nl/s | 0.22 |
| Vacuum Flow at 30 -kPa | Nl/s | 0.15 |
| Vacuum Flow at 40 -kPa | Nl/s | 0.07 |
| Evacuation Time to Reach 10 -kPa | s/l | 0.28 |
| Evacuation Time to Reach 20 -kPa | s/l | 0.56 |
| Evacuation Time to Reach 30 -kPa | s/l | 1.13 |
| Evacuation Time to Reach 40 -kPa | s/l | 2.13 |
Need Help? Call an engineer at 1-802-880-3123
We're open 8:00 am to 5:30 pm ET