Call for pricing
  • MLL400ES
  • 0100742U

Overview

Features

  • Largest compressed air driven pump on the market
  • Energy-saving (ES) available
  • Material: Nitrile (NBR);Al;SS;PPS
  • Item Feed Pressure (Max): 0.7
  • Item Noise Level (Min): 72
  • Item Noise Level (Max): 76
View other configurations.

Description

Ejector Data Specifications

Ejector Specification MLL400
Feed Pressure | MPa 0.6
Air Consumption | Nl/s 28
Vacuum (Max) | -kPa 91
Vacuum Flow at 0 -kPa | Nl/s 92
Vacuum Flow at 10 -kPa | Nl/s 52
Vacuum Flow at 20 -kPa | Nl/s 35
Vacuum Flow at 30 -kPa | Nl/s 18.4
Vacuum Flow at 40 -kPa | Nl/s 9.2
Vacuum Flow at 50 -kPa | Nl/s 6.4
Vacuum Flow at 60 -kPa | Nl/s 4.6
Vacuum Flow at 70 -kPa | Nl/s 2.2
Vacuum Flow at 80 -kPa | Nl/s 0.92
Vacuum Flow at 90 -kPa | Nl/s 0.02
Evacuation Time to Reach 10 -kPa | s/l 0.0015
Evacuation Time to Reach 20 -kPa | s/l 0.004
Evacuation Time to Reach 30 -kPa | s/l 0.007
Evacuation Time to Reach 40 -kPa | s/l 0.015
Evacuation Time to Reach 50 -kPa | s/l 0.03
Evacuation Time to Reach 60 -kPa | s/l 0.05
Evacuation Time to Reach 70 -kPa | s/l 0.08
Evacuation Time to Reach 80 -kPa | s/l 0.15
Evacuation Time to Reach 90 -kPa | s/l 0.41